Home › Forums › Mooshimeter Support › Can't adjust range on graph for channel 2
- This topic has 6 replies, 2 voices, and was last updated 6 years, 6 months ago by
admin.
- AuthorPosts
David
GuestI just got the meter and I am having a hard time getting the graphing mode to display anything useful. As a test I am attempting to graph the voltage change at a incandescent lamp when it is turned on. All I get is useless jagged lines. I can change the scale for the channel that I am not using, but not for the channel that I am using. I have only 2leads connected in c+v ports . I have tried auto and manual ranging for everything. All I get is jagged lines at a scale that is irrelevant to what I am trying to display
admin
KeymasterHi David,
Thanks for the report, I’m looking in to this now. It was reported in this forum thread as well: https://moosh.im/f/topic/manual-scaling-ch2-does-not-work/
If you have model information for you phone that would help too.
Thank you! Sorry for the trouble.
James
Anonymous
GuestAndroid 6.0.1 on Nexus 5
Anonymous
GuestSame problem on HTC ONE running Android 4.4.2
Anonymous
GuestHi James,
the same is on Samsung Galaxy S5 Neo with Android 6.0.1, too.
Additionally it would help, when it was possible to switch off graphing one channel when only using the other one.
Best regards
Dirkadmin
KeymasterJust writing to confirm I can reproduce the issue and am trying to debug it now…
admin
KeymasterWanted to let the thread know I got this figured out and it will be pushed in the next beta – it was an error I made merging in some changes from a user contribution to the project.
Thanks guys!
https://github.com/mooshim/Mooshimeter-AndroidApp/commits/beta
- AuthorPosts